Input Power Error. my unit has an error code of FE and the indoors runs but the compressor does not come on. Standard and Remote Applications with LED M70 Control Board and R-410A. All rights reserved. pliz help me resolve this problem. Either a sensor or too much pressure. Storing the codes allows the property to see the trouble codes at a future time after the condition may have corrected. Does anybody know what to do? Packaged Terminal Air Conditioner (PTAC) ACCESSORIES FR_PTAC_ACC 01/17 Wall Sleeves and Drain Kit Metal Wall Sleeve & Accessories 5304482701 Steel Sleeve – Insulated 5304483759 16" Extended Sleeve – Insulated 5308815304 18" Extended Sleeve – Insulated 5308815305 24" Extended Sleeve – Insulated 5304483760 3" Sleeve Adapter These fully insulated sleeves are … Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. As of about a month ago, the heating module of this unit does not seem to be working -- it only blows cold air on "heat" regardless of the temperat … Hi there, my name is*****’ve got over 10 years in the trade and I’ll be glad to help Please disregard any automated phone request or service requests as they are generated by the website. PTAC-SVX01C-EN 3 *All heat pump units must have electric heat. Trane PTAC-SVX01C-EN Pdf User Manuals. my air-conditioning displays error EC and it’s stops, even though you use a remote it doesn’t respond until you switch it off by socket and then you put it on again that when it work, what the possible problem please help me thanks, FO Fault I understand Freon low but what is meant by Block protection. RATED VOLTS 265 1PHASE B60Hz BTU/HR 12000 AMPS A4. is too high limit/decrease frequency. Comment:*document.getElementById("comment").setAttribute( "id", "ae39756b57303ec69ac96853fcdbd1f5" );document.getElementById("hbe3531a12").setAttribute( "id", "comment" ); Save my name, email, and website in this browser for the next time I comment. We also use third-party cookies that help us analyze and understand how you use this website. Please bear with my responses, actively working on the job site … The email address entered is already associated to his explanation that the wiring to the thermostat is not making a connection.. by simply pointing your Browser to our secure Proliphix Web Site. Never had this happen before and I'm not sure what's causing it. Cool Mode Or Dry Mode: Unit Operate With Compressor Off Fan Mode: Operates As Per User Setting. MyTrane is showing a code PH What does that mean ? Founder of Hays Cooling, Heating & Plumbing. buenas tardes tengo un minisplit frio */ calor de 2 tr. But opting out of some of these cookies may affect your browsing experience. BATTERY LOW ERROR. If there is a code listed, see the unit “Diagnostic Codes” chart for a list of definitions. Malfunction or Protection: Low pressure protection. Malfunction Code Of Outdoor Unit (8/10.5/18kW): Malfunction or Protection: Communication malfunction between indoor/outdoor units, Malfunction or Protection: T3&T4 temperature sensor malfunction, Malfunction or Protection: Power voltage protection, Malfunction or Protection: Fan Protection, Malfunction or Protection: Compressor discharge temperature sensor malfunction, Malfunction or Protection: EEPROM malfunction, Malfunction or Protection: A fan in the Aregion run for more than 5 minutes in Heat mode, Malfunction or Protection: 2 times of E6 protection in 10 minutes, Malfunction or Protection: Communication malfunction between IR341/main board, Malfunction or Protection: Hi-pressure protection, Malfunction or Protection: Low-pressure protection, Malfunction or Protection: Input current protection, Malfunction or Protection: Compressor discharge protection temperature, Malfunction or Protection: Condenser high temperature protection, Malfunction or Protection: Inverter module protection, Malfunction or Protection: Indoor evaporator hi-tempprotection, Malfunction or Protection: Module malfunction, Malfunction or Protection: DC generatrix low voltage protection, Malfunction or Protection: DC generatrix high voltage protection, Malfunction or Protection: MCE malfunction/simultaneously/cycle loop, Malfunction or Protection: Zero speed protection, Malfunction or Protection: Wrong phase protection, Malfunction or Protection: Speed difference>15Hz protection between the front and the back clock, Malfunction or Protection: Speed difference>15Hz protection between the real and the setting speed, Explanation: Compressor down due to protection control of the discharge temperature sensor, Explanation: Error due to condenser temperature sensor when in cooling mode, Explanation: Error of the low pressure switch (Protection control), Explanation: Reverse phase error (Protection control), Explanation: Error of outdoor temperature sensor (Open/Short), Explanation: Error of condenser temperature sensor (Open/Short), Explanation: System down caused by communication error after completion of tracking Mismatching of indoor unit quantity setting error after completion of tracking 5 times, Explanation: Error of discharge temperature sensor (Open/Short), Explanation: Error of temperature sensor in the indoor unit (Open/Short), Explanation: Error of the heat exchanger sensor in the indoor unit (Open/Short), Explanation: Error of electronic expansion valve open in the outdoor unit (when it is detected more than once), Explanation: Error of electronic expansion valve close in the outdoor unit (when it is detected more than once), Explanation: Error of communication between the indoor unit and the wired remote controller, Explanation: Master wired remote controller / slave wired remote controller, Explanation: Polarity error (F1/F2, F3/F4 switched), Explanation: Error of setting option for wired remote controller COM2, Trane Air Conditioner Error Codes Manual PDF. Hopefully, this will only be a problem with the breaker in your home, but it could be a more serious issue in your furnace that warrants an extensive repair. BAYCNHK031 Kit for 15 Amp A Trane hardwire kit BAYHRK001 is direct wired to the building power supply and attached to the PTAC. © 2014-2021 ACErrorCode.com. This website uses cookies to improve your experience while you navigate through the website. Unit stops working. Founder of Hays Cooling, Heating & Plumbing. Chris leads a team of certified technicians who have over 45 years of combined experience and has earned and A+ rating with the BBB and a strong five star rating online. Outside compressor does’nt work no movement serial 4TYK1618A10N, I have Trane air-conditioning ductable AC model TTK042KDOODA …. These cookies will be stored in your browser only with your consent. Required: Hard Wire Kit. Amana Air Conditioner Troubleshooting: Troubleshooting Chart for ECM Variable Speed Air Circulator Blower […] 9, 12 MBH – 60 and 50 Hz ( No LED light on outdoor PCB). For 265V units, if power cord accessory option is se lected, then the cord is only l8" long and must plug into the accessory electrical 265V sub-base. If you notice a continuous light on your Trane that won’t turn off, it means that you will need to replace your furnace’s Furnace Control Board (IFC). Hays Cooling, Heating & Plumbing focuses on providing support to their customers every step of the way, with exceptional service and competitive prices. Necessary cookies are absolutely essential for the website to function properly. PTAC Serial Number Identification Guide SERIAL NUMBER YEAR MANUFACTURED PRODUCTION RUN NUMBER PD H 07 K 3 S E A Engineering Digit Design Series Options S = Standard Nominal Heater Size (@ 230V or 265V) 0 = No Heater 2 = 2.5KW 3 = 3.4KW 5 = 5.0KW Voltage K = 208/230V - 1Ph. Error code 166 Filter by product This button does not work with screen readers. Malfunction or Protection: Compressor current protection. Error 10 Idu Error - Input Power Problem. Unit stops working. This happens when the evaporator coil gets iced up, air filter gets dirty, the system runs low on refrigerant, or when there is a problem in the printed circuit board. If you notice a light on your Trane furnace that is flashing slowly, this means that your furnace is on but it is not calling for heat. - 60Hz. Sign up for the Hays newsletter for exclusive deals. Very little use. Package Terminal, Air Conditioner/Heat Pump. Problem: The air conditioner works but it does not cool the room Possible reasons: 1. No more than a year of use. My 2012 Trane 4TXM6524A1030BA will randomly shut down and throw a “E-1” code. https://www.tradesmandrcool.comTRANE Diagnostic Fault Codes Board blinks twice not knowing code. sir..my split ac working good but in running unit i remove sensor after 10 sec fix now my indoor unit ok working no error but outdoor unit not working outdoor pc borad yello light blink …..plz, Looking for error codes of a trane hide away aircon model nr:MWD536DBOWC, Your email address will not be published. However, if you’re unfamiliar with error codes for furnaces, then you may be unaware of what these codes mean. To get peace of mind, it’s important that you take a look at typical Trane furnace error codes to you learn what these error codes mean so you can get your system the service it needs. Fan Failure Error. The installer is stumped and says its the fan. Unit Stops Working. 8 WATTS 1120 COOLING BTU /HR 7 0 6 23 8 4 AMPS 21 .5 /3 9 WA TS 5 0/3 2 EL CTRI H ATING 63229919466 Warning: Use on Single Outlet Circuit Only P A CK G ED T RM I NL O Al s oV erif dI n caW th Egy S DO T P u Could you tell what it means and how to resolve the problem? In Indonesian my apartment ac controller displays Fr, what is this fault code. If the error code light on your Trane furnace will not come on no matter what your furnace is doing, it means that you need to check your power source. The 79 fault code means that the low pressure switch is released. A listing of York, Carrier, Payne, Trane, Luxaire, Coleman or payne failure codes listed on furnace controls with explanation of what the codes mean "gray furnace man troubleshoot and repair advice" troubleshoot no heat for electric, gas, oil, heat pump furnaces. Display of indoor unit Running Indoor Cooling Indoor Heating Indoor Yellow Outdoor Red Outdoor Green Outdoor Name of malfunction; E2: 2: 3: Anti-freezing protection You do not have to accept phone requests unless you want that service. amana air conditioner codes. The room temperature measured by the wireless remote thermostat or indoor ambient thermistor active sensor falls below 40°F. Operates indoor unit and outdoor unit as per user setting. Error 03 Filter choke error -Clean the filter. PTAC ETAC ETAC2 CP- Sea Coast Protection Revision Level Cooling Capacity 07 - 7,000 BTUH 09 - 9,000 BTUH 12 - 12,000 BTUH 15 - 15,000 BTUH Model Type Electrical Rating HP -Heat Pump 230V - 208/230V 60Hz 1PH HC - Heat/Cool 265V - 265V 60Hz 1PH ETAC2 12 HP 230V A -A Example: ETAC2-12HP230VA-A Fig. Action to be taken by user: Contact service technician. Cool Mode Or Dry Mode: Unit Operate With Compressor Off Fan Mode: Operates As Per User Setting. Building Performance and Systems Engineers. R = 265V - 1Ph. Malfunction or Protection: Outdoor condenser high temperature protection. View online or download Trane PTAC-SVX01C-EN Installation, Operation And Maintenance Manual • An A2 error may indicate an exhaust leak from the combustion chamber or may simply indicate a bad overheat cutoff fuse. Malfunction Code Of Outdoor Unit (12/14/16kw): Malfunction or Protection: M_Home unmatching, Malfunction or Protection: Communication fault of the outdoor chip and the indoor chip, Malfunction or Protection: Communication error between Main board and IR341, Malfunction or Protection: Outdoor unit sensor fault, Malfunction or Protection: Voltage protection fault, Malfunction or Protection: Direct-current fan fault, Malfunction or Protection: Heating fan fault in the area A lasts for 5 minutes, Malfunction or Protection: There are two times E6 fault in 10 minutes (recovery will be after power off), Malfunction or Protection: The cooling fin high temperature protection, Malfunction or Protection: High pressure protection, Malfunction or Protection: Low pressure protection, Malfunction or Protection: Compressor current protection, Malfunction or Protection: Discharge temperature protection, Malfunction or Protection: Outdoor condenser high temperature protection, Malfunction or Protection: IPM modules protection, Malfunction or Protection: Evaporator high temperature protection, Malfunction or Protection: Typhoon protection. Unit Stops Working. The only time this would be a problem is if you’ve raised your thermostat and your Trane does not respond, in which case you’ll need to think about heating repair in Phoenix. I have to shut breaker off to get it going. Error code: oE, on heat mode. Error 05 Outdoor Temp Sensor Failure Contact Service Technician. BAYHWRK001 Connector for Hardwire. Amana Diagnostic Codes; If there are no active failures or lockouts, the display will show a double dash, “- -”. Error 09 Low battery please change the battery. Overheat Cutoff Fuse • The overheat cutoff fuse is a thick white wire (similar to a fusible link) that wraps around the heat exchanger. Chris Hays. Return air temperature sensor open/short circuited, Evaporator temperature sensor open/short circuited, Indoor unit liquid valve temperature sensor open/ short circuited, Indoor gas valve temperature sensor open/short circuited, IPM temperature sensor open/short circuited, Outdoor ambient temperature sensor open/short circuited, Outdoor unit condenser mid-tube temperature sensor open/short circuited, Discharge temperature sensor open/short circuited, Compressor phase current sensing circuit error, System charge shortage or blockage protection, Communication line mis-connected or expansion valve error, Compressor phase loss/reversal protection, Frequency restricted/reduced with whole unit current protection, Frequency restricted/reduced with IPM current protection, Frequency restricted/reduced with high discharge temperature, Frequency restricted/reduced with anti-freezing protection, Frequency restricted/reduced with overload protection, Frequency restricted/reduced with IPM temperature protection. Mar 13, 2019 - Easy-to-use list of Trane air conditioner error codes and their explanation. These cookies do not store any personal information. Error 08 Communication Error Contact Service Technician. This code usually means a problem only when the furnace is constantly calling for heat and not responding to your thermostat’s signals. Indoor Temp Sensor Error (Room). 23.Oca.2021 - Air Conditioner fault code list, All brands, All Models. in accordance with the NEC™ and all local codes, ordinances and regulations. 22-5186-0169-1248FEATURESThe itself and loses all the settings.